86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


Amikon Limited

Products >> TRICONEX 3664 TRICON 3664 CPU MODULE

TRICONEX 3664 TRICON 3664 CPU MODULE

Build Your Online Product Catalogs?



Description
Product Name: TRICONEX 3664 TRICON 3664 CPU MODULE
Supply Ability: 2 pcs
Related proudcts triconex 3664, 3664, 3664,
Specifications new and original
Price Term: FOB
Port of loading: Xiamen
Minimum Order 1 pcs
Unit Price: 123

Skype^ : dddemi33
Sales&Manager : Tiffany Guan
RFQ#e-mail : sales8@amikon.cn
Whats@app : +86 18030235313

TRICONEX 3664 TRICON 3664 CPU MODULE

TRICONEX 3664 TRICON 3664 CPU MODULE

TRICONEX 3664 TRICON 3664 CPU MODULE

General Environmental and EMC Specifications Other than the optional conformal coating of all PCB assemblies, the Tricon is not explicitly protected against dust, corrosive atmospheres or falling debris. Atmospheric and airborne-particle protection must be provided by housing the Tricon in an appropriate NEMA-rated enclosure. Operating Temperature 32กใ to 140กใ F (0กใ to 60กใ C), ambient, as measured at the bottom of the chassis, per IEC 60068-2-1 Test Nb Storage Temperature -40กใ to 167กใ F (-40กใ to 75กใ C), per IEC 60068-2-14, Test Na Relative Humidity 5% to 95%, non-condensing, per IEC 60068-2-2, Test Bb, and IEC 60068-2-3 test Db Sinusoidal Vibrations per Axis 2 G @ 10 to 150 Hz, per IEC 60068-2-6, Test Fc Shock 15 G for 6-11 ms in each axis, per IEC 60068-2-27 Electrostatic Discharge IEC 61000-4-2, 8 kV air, 4 kV contact Conducted Susceptibility IEC 61000-4-4, Fast Transient/Burst, 2 kV power, 1 kV signal lines and IEC 61000-4-5, Surge Withstand, 2 kV CM AC power lines, etc. IEC 61000-4-6, RFI, 0.15-80 MHz, 10V Radiated Susceptibility IEC 61000-4-3, 26-1000 MHz, 10 V/m and IEC 61000-4-8, 50-60 Hz, 30 A/m Conducted Emissions CISPR 16, Class A, 0.15-30 MHz, 73-79 db when installed per the guidelines of the P&I Guide Radiated Emissions CISPR 11, Class A, 30-1000 MHz @ 10 m, 4-47 db when installed per the guidelines of P&I Guide Cable Flame Test Rating1 1.Applies to cables shipped after April 1, 2009. Interface cables (connect external termination panels to I/O modules): FT4 Vertical Flame Test-Cables in Cable Trays per C.S.A. C22.2 No. 0.3-92 Para 4.11.42 I/O bus cables (connect chassis): FT6 Horizontal Flame & Smoke Test-per C.S.A. C22.2 No. 0.3-92 Appendix B3


53MC5412A25BAXXDXXXX 53MC5000 Controllers
53MC5412A25BAXXXXXXA 53MC5000 Controllers
53MC5412A25BAXXXXXXX

Contact Us
Company: Amikon Limited
Contact: Ms. Tiffany Guan
Address: 32D floor,Guomao Build,No.388,Hubin South Road, Siming District,
Postcode: 361009
Tel: 18030235313
Fax: 05925173279
E-mail:         


Copyright© Amikon Limited All Rights Reserved.
Tel : 18030235313 Fax : 05925173279
Powered by 86exporter.com